Uni-Motion User Guide has been moved to this page.
Use in upper body mode
We will explain how to move the avatar in cooperation with virtual motion capture.
Check Uni-studio settings.
*When changing Uni-studio settings, be sure to turn on the power of all Un-Sensors. If the Uni-sensor is powered off, the setting changes will not be reflected.
The recommended settings for upper body mode are:
(1) Magnetic correction: ON
② Refresh rate: 60 (LP)
(3) Fracture prevention: OFF
(4) Auto correct: OFF
When using with magnetic correction OFF, please set as follows.
①Magnetic Correction: Head Only ON
② Refresh rate: 60 (LP)
(3) Fracture prevention: OFF
④ Auto correct: ON
Carry out magnetic calibration
When using with magnetic correction ON, it is necessary to perform magnetic calibration. Follow this guide to perform magnetic calibration.
Initial tracker setup
Perform the initial settings of the tracker from the setting screen.
① Open the setting screen from the gear icon at the bottom right of the screen.
② From the menu on the left side of the screen, open "Movement mode" and click "Upper body mode default".
③ Select "Tracker transmission" from the menu on the left side of the screen, and click "Set upper body mode default".
④Close the setting screen, return to the top screen, and confirm that the avatar is displayed on the screen.
Set VMC Protocol
-
Check Send tracker information with VMCProtocol
-
Align port with virtual motion capture
-
press Apply
Set tracker assignments
-
Select the tracker named "Uni_site" as shown in the image. Select "Do not assign (automatic detection)" for all remaining parts.
-
Set all hand tracker offsets to 0.
Attach the sensor to the body
attach the sensor to the body
Put the Uni-sensor in the sensor holder and put on the belt.
Attach the chest sensor (1) to the head, the waist sensor (2) to the chest, the thigh sensors (3)(5) to the upper arm, and the shin sensors (4)(6) to the lower arm. Please refer to the sensor number sticker and the avatar on the Uni-studio screen for the mounting position.
* Wear the head and chest belts so that the Uni-sensor is in front.
*Since there is no special belt for the arm, it is necessary to devise a method such as wrapping it around for two weeks.
Uni-studio Simple Calibration
・Please wait 10 to 20 seconds after powering on the Uni-sensor before performing calibration.
・Please make sure that the chest sensor is installed parallel to the chest plate.
1. Turn on the Uni-sensor, then click the "Calibrate" button on the Uni-studio top screen.
* The image is when 8 Uni-sensors are connected.
2. Follow the instructions on the screen to calibrate in I-pose and S-pose.
Calibration can be done while sitting in a chair.
Complete calibration with virtual motion capture
1. Press "Calibrate" from the virtual motion capture control panel.
2. Make sure MR synthesis mode is selected and perform calibration.
is complete.
If the cooperation between Uni-motion and VMC does not work
Check the tracker information transmission settings from the Uni-station settings screen.
① Open the setting screen from the gear icon at the bottom right of the screen
Check the tracker information transmission settings from the Uni-station settings screen.
① Open the setting screen from the gear icon at the bottom right of the screen.
② Select "Send tracker" from the menu on the left side of the screen, and confirm that "Send tracker information with VMC Protocol" is ON.
(3) Confirm that the displayed port number matches the port number on the VMC setting screen side.
④ If the port numbers are different, match the VMC and Uni-station port numbers.