top of page

Uni-sensor

I will explain how to use Uni-sensor.

Description of Uni-sensor

Indicator LED.png

Part/Operation

  • power switch

Press the switch briefly to turn on the power. The same is true when cutting. Calibration data is saved when the power is turned off.

  • config mode

- When entering config mode from a PC

With the sensor powered on, use the Uni-motion Settings Manager and press the "Enter Config Mode" button.

- manually enter to config mode

With the power on, press and hold the power switch for 5 seconds or more, then release the switch.

 

To exit config mode, short press the switch or press "reboot sensor" in the Uni-motion Settings Manager.

  • indicator LED

Lit state: The sensor information is being sent to the Uni-station.

Blinking slowly: Disconnected from the Uni-station and waiting.

Blinking state: Config mode.

wait_blink.gif
config_blink.gif

config mode

​ (5 flashes per second)

standby mode

​ (flashing once every 2 seconds)

  • auto off​​​

If it cannot connect to Uni-station for 3 minutes (default), it will automatically power off.

  • Sensor firmware update

​ update is here

​ Specifications